Small Imaging Detectors with Time Resolution (3D Detector Systems)
DLD – 3030, DLD – 3636, DLD – 4040 (customized up to DLD – 4545)

Imaging DLD with delay line anode area up to 45 x 45 mm².
High count rates, small deadtimes, compact design.
Typical applications: Electron Spectroscopy, Time Resolved Photoemission Electron Microscopy (TOF-PEEM), Mass Spectrometry (TOF-SIMS, RIMS, MALDI), X-ray microscopy, X-ray holography, X-ray spectroscopy.
Additional information (PDF).
Please visit our partner Specs GmbH for information about the electron spectrometers used in conjunction with our delay line detectors
Large Imaging Detectors with Time Resolution (3D Detector Systems)
DLD – 6565, DLD – 8080, DLD – 120120

Imaging DLD with delay line anode area up to 120 x 120 mm². High count rates, large active detector areas, high lateral resolution, large pixel numbers (up to 10,000 x 10,000).
Typical applications: Medium Energy Ion Scattering (MEIS), Atom Probe Microscopy (APM), Field Ion Microscopy (FIM), X-ray microscopy, X-ray holography, X-ray spectroscopy.
Line Detectors With Time Resolution (1D-2D Detector Systems)
DLD – 43, DLD - 64

Line detectors for 1D (multi channel) / 2D (multi channel + time) detection in electron spectroscopy as well as for X-ray, UV, and charged particle applications.
Typical applications: multi channel detection in electron energy analyzers, X-ray and UV-diffraction.
Application notes (PDF).
Multi-Hit 4-Quadrant DLD Systems
DLD – 3030 – 4Q
4-quadrant delay line detector for parallel multi hit detection of electrons, ions, UV and X-ray with burst count rates of above 100 MCPS.
Typical applications: Particle detection with extremely high burst count rates in pulsed experiments, e.g. mass spectrometry (TOF-SIMS, RIMS, MALDI).
DLDs for Use with a Photoemission Electron Microscope (PEEM)
DLD - 3636
Standard delay line detector for photoemission electron microscopes. Delay line anode area: 36×36 mm²; mounting flange: DN63CF.
Additional information (PDF).
Interchangeable DLD - 4040 - IC

DLD mounted on a linear drive for in-situ exchange between DLD and the imaging unit of the PEEM. Delay line anode area:
40×40 mm²; mounting flange: DN63CF or DN100CF.
Additional information (PDF).
Application examples (PDF).
Time Resolving X-ray, EUV Detectors
DLD - 3636 - XR

DLD with polyimid window for the laterally and timeresolved detection of X-rays. Delay line anode area: 36 x 36 mm².
Additional information (PDF).

Surface Concept is an expert in custom designed delay line detectors. We can build all parts of delayline detectors (active areas, housings, mounting flanges) adapted to the customer's application.